Xylem STORM 3 UPGRADE User Manual

Upgrade to storm

Advertising
background image

UPGRADE TO STORM

INSTALLATION INSTRUCTIONS

Take a picture of the inside of your enclosure
for reference, put on your anti-static wristband
and attach the clip to the ground lug located
on the bottom of the EcoNet enclosure.

The ground lug should already be wired to
a ground rod, which is buried in the ground.

Bottom of Enclosure

1

3

Green Connectors

What You Need

1

Required

Quantity

Storm 3 Data Logger

1

Mounting plate

1

Phillips screwdriver that is 9.5” long

1

Small flat blade screw driver (2mm wide blade) 1
Adjustable wrench

1

Laptop / Smart Phone / Tablet with Wi-Fi

1

Storm Central Registration ID

1

Suggested

Quantity

Safety

glasses

1

White

electrical

tape

1

Pen

1

Anti-static

wristband

1

Camera

or

notepad

1

Digital

multimeter

1

*Activate your stormcentral.waterlog.com account and log in prior to going out to your

equipment site. Contact WaterLOG Technical Support at 435.227.1767 for further ques-

tions, and to obtain access to the Storm Central Service. Refer to the ‘Storm Central Getting

Started Guide’ for detailed instruction on set up with Storm Central.

2

Remove the three green five position
connectors from the side of the EcoNet.
Remove and label the individual wires as
A-F, from the green five position Phoenix
connectors:

To avoid short circuits, cover the wire
ends with electrical tape until it is time for
reconnection in Storm 3 connectors.

Connector 1
A. GND black wire from 4th position of 1st connetor.

B. SDI-12 purple wire from 5th position of 1st connector.

Connector 2
C. GND green wire from 3rd position of 2nd connector

D. GND black wire from 4th position of 2nd connector

E. VBATT red wire from 5th position of 2nd connector

Connector 3
F. +12V Out red wire from 5th position of 3rd connector

Anti-static wrist band