Installation & Instructions for Instant Hot Water Recirculating Systems

ACT 909 Tankless Mounting Bracket Instructions
Installation, Operation and Service Instructions

Laing Thermotech

Instruction Manual IM-28

Lift timer cover on the pump, and slide the switch to the “Off”

position. Turn off the water using the angle stop valves under

your sink. Unplug the pump, and disconnect the hoses from the

pump housing (Bronze top).

*Please note : For a currently installed pump, begin with figure 1. For an uninstalled pump begin with figure 5.

fig. 1

Using an Allen wrench, remove one of the bolts that connects

the pump motor drive unit to the housing.

fig. 2

Place the bolt through the bracket ear.

fig. 3

Screw the bolt with the bracket ear back into place, and

tighten. Repeat steps 2 through 4 on the other bolt. (DO ONE

SIDE AT A TIME ONLY, DO NOT REMOVE BOTH BOLTS AT THE

SAME TIME).

fig. 4

Locate the 4 rubber grommets.

fig. 5

Place the grommets in the side holes of mounting bracket.

fig. 6