1. Mechanical Seals on Shaft



DISASSEMBLY



NOTICE: Numbers that appear in parenthesis ( ), such as

(1-939-9), may be used to order replacement parts.

1. Close valves on suction and discharge sides of pump. (If

no valves have been installed, it will be necessary to drain

the system.)

1

8

CAUTION: Extreme Temperature Hazard



Allow pump temperatures to reach acceptable levels

before proceeding. Open drain valve, do not proceed until

liquid stops coming out of drain valve. If liquid does not

stop flowing from drain valve, isolation valves are not seal-

ing and should be repaired before proceeding. After liquid

stops flowing from drain valve, leave drain valve open and

continue. Remove the drain plug located on the bottom of

the pump housing. Do not reinstall plug or close drain

valve until reassembly is completed. Failure to follow these

instructions could result in property damage and/or moder-

ate personal injury.

WARNING: Unexpected Start-up Hazard



Disconnect and lock out power before servicing.

Failure to follow these instructions could result in serious

personal injury or death and property damage.

Photo 1 – Assembly Section: Pump With Mechanical Seals on Shaft

Photo 2 – Pump with Mechanical Seals



Impeller rings can be added–

Optional Extra.

IMPELLER WEAR RING

Optional Extra.

BALANCED

MECHANICAL SEAL

NOTE:

Standard mechanical seal pip-
ing can be modified for filter or
external flushing arrangement.