h. Connect the red flow switch wire (HH) to the

“Hot” power supply wire (JJ). Cap with a wire

nut and seal with electrical tape.

HH

red

JJ

“Hot”

i. Cover and properly secure the electrical

junction box (CC).

CC

a. Turn on the electrical power to the flow switch.

Initiate flow through the flow switch.

OFF

ON

b. Observe the device being activated by the flow switch, or measure the flow rate

to determine if the flow switch is activating when desired. If the flow switch isn ’t

activating when desired, follow Step 7 to adjust the sensitivity.

STEP 6 - Testing

6

For all installations

STEP 5 - continued

g.2.

For NO FLOW Mode of Operation

If the flow switch will be used to actuate a signal,

alarm, or other device when no flow occurs, connect

the blue flow switch wire (FF) to the appropriate wire

from that device (EE). Cap with a wire nut and seal

with electrical tape.
If the flow switch will also be used to actuate another

device when flow occurs, connect the yellow flow

switch wire (DD) to the appropriate wire from that

device (GG). Otherwise, cap the yellow wire (DD)

with a wire nut and seal with electrical tape.

FF

blue

GG

DD

yellow

EE

Advertising