Xylem MM 713B Series 93/193 and 94/194 Replacement Floats User Manual

Page 3

Advertising
background image

3

d. Prepare Flange Surfaces

Scrape and clean flange surface

on

control body and control head.

150-14

92-68

CONDUIT FITTING

TERMINAL PANELS

HEAD ASSEMBLY

CONTROL BODY

B

A

C

e. Replace Head Assembly

• Slide

flange gasket (150-14 for Series

93/193 units and

92-68 for Series 94/194

units) over

float ball and float stop

plate.

• Insert

head assembly by carefully guiding

float ball into control body.

• Align Gasket and install head bolts (

C).

• Using a torque wrench, tighten

head bolts

in an alternating star pattern. Tighten to
14-20 ft•lbs for Series 93 models. Tighten
to 17-21 ft•lbs for Series 94 models.

• Install

conduit fitting with attached

wires and secure with two screws (

B).

Reconnect wiring to terminal
panels
in exactly the same position
as removed.

• Replace

switch cover and fasten

with two screws (

A).

IMPORTANT: Care must be taken not to
damage flange surfaces. Nicks, scrapes
or gouges may cause the flange to leak
when in service.

Advertising