d. Prepare Flange Surfaces

Scrape and clean flange surface

on

control body and control head.

IMPORTANT: Care must be taken not to
damage flange surfaces. Nicks, scrapes
or gouges may cause the flange to leak
when in service.

e. Replace Head Assembly

• Slide

flange gasket over float ball.

• Insert

head assembly by carefully guiding

float ball into control body.

• Align Gasket and install head bolts.

• Using a torque wrench, tighten

head bolts

in an alternating star pattern. Tighten to
14-20 ft•lbs.

Reconnect wiring to terminal
panels
in exactly the same position
as removed.

• Replace

switch cover and fasten

with screws. On Model #65, cover and
housing surfaces must be free of grit and
debris for proper seal. On Model #165,
replace the cover gasket.