Thermostat troubleshooting flowchart, Table 4 – John Wood Commercial - AJWS User Manual

Page 23

Advertising
background image

THERMOSTAT TROUBLESHOOTING FLOWCHART

23

0

1

2

3

4

5

6

7

8

9

0°C

32648 31026 29495 28049 26682 25389 24166 23010 21915 20879

10°C

19898 18968 18088 17253 16461 15710 14998 14322 13680 13071

20°C

12492 11942 11419 10922 10450 10000 9572

9165

8778

8409

30°C

8057

7722

7403

7099

6808

8532

6268

6016

5775

5546

40°C

5327

5117

4917

4726

4543

4368

4201

4042

3889

3742

50°C

3602

3468

3340

3217

3099

2986

2878

2774

2675

2579

60°C

2488

2400

2316

2235

2157

2083

2011

1942

1876

1813

70°C

1752

1693

1637

1582

1530

1480

1432

1385

1340

1297

80°C

1256

1216

1177

1140

1105

1070

1037

1005

974

944

90°C

916

888

861

835

810

786

763

741

719

698

40°F

26109 25400 24712 24045 23399 22771 22163 21573 21000 20445

50°F

19906 19383 18876 18383 17905 17440 16990 16553 16128 15715

70°F

11884 11592 11308 11032 10763 10502 10248 10000 9760

9526

90°F

7333

7165

7000

6839

6683

6531

6383

6238

6098

5961

100°F

5827

5697

5570

5446

5326

5208

5094

4982

4873

4767

120°F

3758

3679

3602

3527

3453

3382

3312

3244

3177

3112

140°F

2488

2439

2391

2344

2298

2253

2209

2166

2124

2083

160°F

1688

1656

1625

1595

1566

1537

1509

1481

1454

1427

180°F

1170

1150

1129

1110

1090

1071

1053

1035

1017

999

190°F

982

965

949

933

917

901

886

871

857

842

200°F

828

814

801

788

775

762

749

737

725

713

Resistance (K ohm s)

Tem perature

Sensor Resistance vs. Tem perature

Table 4

Replace

set pot.

Replace

thermostat

circuit board.

Replace

bad

sensor(s).

Check

damper.

Take ohm reading

from upper and

lower sensors

and compare with

chart in Table 4.

(A temp. reading

from a water

sample taken

from T&P valve is

also needed for

this test).

Check orange

wire from ECO

board to

damper for 24V.

Check purple

wire from ther-

mostat for 24V.

Will ECO board

reset?

High water

temp.

Check ECO

and ICM.

Is ECO light

“ON”?

Replace ECO

board.

Slowly turn set

pot from low to

high. Reading

should change

smoothly with

no skips, jumps

or glitches.

With an ohmmeter

set at X1, check
orange wires on

set pot. (3,000

ohms at lowest

setting & 0 ohms

at highest setting.)

No voltage or

low voltage
from purple

wire between

thermostat

board & ECO

board.

OHMs
reading no good

OHMs show OK

Yes

No

No

No

No

No

Yes

Yes

Yes

OK

Has bad spots