John Wood Commercial - AJWSC User Manual

Page 27

Advertising
background image

– 27 –

Detect Conditions

Alarm (ERROR) Name

Control Action

Service

Suggestion (After

Error Matured)

Detection

Time

Remote

Display

Valve relays
shorted/open, other
internal electronic
failures

SLO_ELECTRONICS

Soft lockout.

Replace control.

All time.

SoftLockout

Flame out of
sequence.

SLO_FLAME_SEQ

Soft lockout.

Check gas supply,
burner and
harness.

During a
heating cycle.

SoftLockout

Flame detected
before trial.

FLAME_IN_PREPURGE

Soft lockout.

Check gas supply,
burner and
harness.

Before ignition. SoftLockout

Flame detected after
trial.

FLAME_IN_POSTPURGE Soft lockout.

Check gas supply,
burner and
harness.

After a heating
cycle.

SoftLockout

Sensor 1 or Sensor
2 reporting greater
than 200°F.

OVER_TEMP

Non-volatile Hard
Lockout for Europe.
Auto-reset for
domestic.

Check Appliance
operation and limit
sensor.

All time.

OverTemp

Valve relays welded
5 times.

ELECTRONICS

Non-volatile Hard
Lockout for Europe.
Auto-reset for
domestic.

Replace control.

During a
heating cycle.

Hard Lockout

Table 6 (cont’d)