Extron Electronics DMP 64 Setup Guide User Manual

Disconnect power and mount the dmp 64, Connections a, Dmp 64 • setup guide

Advertising
background image

IMPO

RTAN

T:

Go to www

.extron.com

for the

complete user guide

, installation

instructions,

and specifications.

Receive (Rx)

Transmit (Tx)

Ground ( )

Bidirectional

RS-232

Device

Ground ( )

Receive (Rx)

Transmit (Tx)

Rx

Tx

Do not tin
the wires!

Disconnect Power and Mount the DMP 64

Disconnect power to the DMP 64 and turn off all devices connected to it. The DMP 64 is housed in a half rack width, 9.5 inches
deep, 1U high metal enclosure that can sit on a table with the provided rubber feet or can be rack mounted. Select a suitable
mounting location, then choose an appropriate mounting option.

Connections

a

Connect the Power Supply — The included power supply is prewired.

Plug the captive screw connector into the DMP 64 power jack.

b

Mic/Line Inputs — Attach up to six microphone or mono line level

devices, balanced or unbalanced, to the DMP 64 using the audio input
wiring diagram shown at right.

c

Connect the Audio Outputs — For balanced or unbalanced mono audio

output, connect an audio output device to each of the four outputs. Wire
the connectors as shown in the audio output wiring diagram shown at
right.

d

Connect the I/O Ports — To control or monitor external devices, connect

up to six digital I/O ports (connections not shown). See the DMP 64 User
Guide
for additional information.

RESET

DMP 64

POWER

12V
1.0A MAX

LAN

1

2

3

4

5

6

4

5

6

1

2

3

4

Tx Rx G

RS-232 (2)

Tx Rx G

RS-232 (1)

4 5 6 G

1 2 3 G

MIC

+48V

1

3

2

MIC/LINE INPUT

S

OUTPUTS

I/O

REMO

TE

This guide provides basic instructions for an experienced technician
to install the DMP 64 ProDSP

Digital Matrix Processor and

DSP Configurator

software. For additional information see the

DMP 64 User Guide found at

www.extron.com

.

IP Address: 192.168.254.254

Subnet Mask: 255.255.0.0

Default Gateway: 0.0.0.0

DHCP: OFF

DMP 64 • Setup Guide

ATTENTION:

For unbalanced audio outputs, connect
the sleeves to ground.

DO NOT connect the sleeves to the
negative (–) contacts.

e

Connect a Control System — There are three options to connect a

control system: LAN, RS‑232, and USB. Extron recommends using the
LAN port for configuration and remote control of the DMP 64.
LAN — Using a standard Ethernet cable, connect to a network via the LAN port (

â

). The

table at right shows the default network settings.

NOTE:

To connect the DMP 64 directly to a computer, use a crossover Ethernet

cable.

RS-232 — Connect the host RS‑232 cable to the rear panel of the switcher (

à

) using the

provided 3‑pole captive screw connector (see the wiring diagram at right).
USB — Connect the host USB port to the front panel configuration port, (not shown), using
a USB A to mini‑B cable. The USB connection should be used only for configuration. Use
the RS‑232 or LAN port for remote control of the DMP 64.

When all connections have been made, power up the input and output devices, then apply
power to the DMP 64.

" (5 mm) MAX. (typ)

3

16

Audio OUTPUT Wiring

Unbalanced Output

Tip

Sleeve

NO Ground Here

Balanced Output

Tip

Sleeve

Ring

Audio INPUT Wiring

Balanced Input

Sleeve

Ring

Tip

Tip

Sleeve

Jumper

Unbalanced Input

Advertising