Resolutions and refresh rates, The table, Blocks. see – Extron Electronics DSC 301 HD User Guide User Manual

Page 24

Advertising
background image

The viewable device status information is:

•

device internal temperature (in degrees F and C)

•

the current active input details (resolution, signal format, and total lines)

•

output resolution and refresh rate and output format

•

AFL status (locked or disabled)

•

HDCP status (input status and HDMI output status)

•

Display Info (resolution and refresh rate)

•

Firmware build details

Resolutions and Refresh Rates

In addition to the 83 factory rates, there are also three custom, user-defined or captured
rates available (C1 - C3). When no rate is captured or uploaded to any of the custom
slots, they revert to the default setting — 720p/60 Hz.

Resolution

23.98 Hz

24 Hz

25 Hz

29.97 Hz

30 Hz

50 Hz

59.94 Hz

60 Hz

75 Hz

Custom 1 through 3

For captured or uploaded EDID tables

640 x 480

X

X

X

800 x 600

X

X

X

852 x 480

X

X

X

1024 x 768

X

X

X

1024 x 852

X

X

X

1024 x 1024

X

X

X

1280 x 768

X

X

X

1280 x 800

X

X

X

1280 x 1024

X

X

X

1360 x 765

X

X

X

1360 x 768

X

X

X

1365 x 768

X

X

X

1366 x 768

X

X

X

1365 x 1024

X

X

X

1440 x 900

X

X

X

1400 x 1050

X

X

1600 x 900

X

X

1680 x 1050

X

X

1600 x 1200

X

X

1920 x 1200

X

X

480p

X

X

576p

X

720p

X

X

X

X

X

X

*

1080i

X

X

X

1080p

X

X

X

X

X

X

X

X

2048 x 1080

X

X

X

X

X

X

X

X

*

= default value

Figure 15.

Resolution and Refresh Rates

When a new custom rate is captured or uploaded, the On-screen Display (OSD)
dynamically updates with the new rate for that custom slot. For example, if a custom
480p EDID is uploaded to slot C1, the LCD would read “C1: 720x480”. These three
custom slots are shared between custom output resolutions (based on preferred timings 1
block) and custom EDID tables, which can be assigned to any input.

DSC 301 HD • Operation

18

Advertising