Extron Electronics FOX RS 104 User Guide User Manual
Page 20

FOX RS 104 RS-232 Inserter • Remote Control
14
X1#
= Number of open connections
0 – 200
X1$
= Password
12 alphanumeric characters
NOTE: The HTML language reserves certain characters for specific functions (see “
X1%
= DHCP
0 =off, 1 = on
X1^
= Baud rate
9600, 19200, 38400, 115200
X1&
= Parity
odd, even, none, mark, space (Only the first letter required.)
X1*
= Data bits
7, 8
X1(
= Stop bits
1, 2
X2)
= Port type (always 0 = RS-232)
X2!
= Verbose mode
0 = clear/none (default for Telnet connection) 2 = tagged responses for queries
1 = verbose mode (default for RS-232)
3 = verbose mode and tagged for queries
NOTE:
If tagged responses is enabled, all read commands return the constant string and the value as the set command does
(for example, the read matrix name command,
E
CN
}
, returns Ipn•
X%]
).
X2@
= Port timeout interval (in 10-sec. increments)
1 (= 10 seconds) – 65000 (default is 30 = 300 seconds = 5 minutes)
X2#
= Direct access port map
0
(= disabled) or
1024
and up (default is
2001
)