Making connections, Making connections -4, Connect the hardware – Extron Electronics Fiber Matrix 6400 User Manual

Page 9: Installation, cont’d

Advertising
background image

Refer also to the Fiber Matrix 6400 Switcher User’s Manual at

www.extron.com

.

Refer also to the Fiber Matrix 6400 Switcher User’s Manual at

www.extron.com

.

Making connections

a

Fiber optic connectors and LEDs

W

This unit outputs continuous invisible light, which

may be harmful and dangerous to the eyes; use with

caution. For additional safety, plug the attached dust

caps into the optical transceivers when the fiber optic

cable is unplugged.

N

Ensure that you use the proper fiber cable for your I/O

board. Typically, singlemode fiber has a yellow jacket and

multimode cable has an orange jacket.

N

The Fiber Matrix 6400 uses one connector on the block as

an input and the second connector on the same block as a

separate output.

Ä

Input connector —

Connect a fiber optic

cable between each Input

LC connector and a

FOX 500 Tx or any other

compatible Extron FOX 500

device.

N

Or, for the FOX 500 serial

return, (receiver-to-transmitter)

function, connect the free end

to the Optical 2 connector on a

FOX 500 Rx receiver.

Input LED —

When lit,

the link is active (light is

received).

Å

Output connector —

Connect a fiber optic cable

between each output LC

connector and a FOX 500 Rx or any

other compatible Extron FOX 500

device.

N

Or, for the FOX 500 serial

return, (receiver-to-transmitter)

function, connect the free end

to the Optical 2 connector

on a FOX 500 Tx

transmitter.

Output LED —

This LED is

always lit.

b

BNC connectors —

Ç

Multi-rate SDI Input connectors — Connect HD-SDI, SDI,

or 3G-SDI video inputs to these BNC connectors.

É

Multi-rate SDI Output connectors — Connect digital

displays to these BNC connectors.

c

Ethernet port — If desired, connect a network WAN or LAN

hub, a control system, or a computer to the Ethernet RJ-45 port.
Network connection

— Wire as a patch (straight) cable.

Computer or control system connection

— Wire the interface

cable as a crossover cable.

N

The factory default IP address is 192.168.254.254.

d

Remote port — If desired, connect a control system or computer

to the rear panel Remote RS-232/RS-422 port.

RS-232 Function

Pin

Function

1
2
3
4
5
6
7
8
9

TX

RX

Gnd




Not used
Transmit
Receive
Not used
Ground
Not used
Not used
Not used
Not used

TX–

RX–

Gnd

RX+

TX+

Not used
Transmit (–)
Receive (–)
Not used
Ground
Not used
Receive (+)
Transmit (+)
Not used

RS-422

5

1

9

6

Figure 2-6 —

Audio output connector wiring

e

Power connector — Plug the switcher into two grounded AC

sources.

N

For reliability, connect the Redundant power cord to either

an uninterruptible power source or to a power source that

is completely independent from the primary power source.

f

Primary and Redundant power supply indicator LEDs —

Green —

Indicates that the associated power supply is

operating within normal tolerances.

Red —

Indicates that the associated power supply is operating

outside the normal tolerances or has failed. See chapter 5,

Maintenance and Modifications“ to replace the power supply.

OUT

IN

OPTICAL

2* 1

*

OPTIONAL FOR

RETURN DATA

LINK

LINK

OPTICAL

FOX 500 Tx

Transmitter

FOX 500 Rx

Receiver

Fiber Matrix

6400

Switcher

1 2*

*

OPTIONAL FOR

RETURN DATA

LINK

LINK

1b

1a

Fiber Matrix 6400 Switcher • Installation

Installation, cont’d

2-4

Fiber Matrix 6400 Switcher • Installation

2-5

Advertising