COMMAND
DESCRIPTION
RESPONSE
VOLLoxxx
Set the output volume for only left channel of output ‘o’ to value ‘xxx’.
1 <= o <= 8; 000 <= xxx <= 255 decimal.
In Direct Mode the [VOLLoxxx] command controls all left outputs
simultaneously regardless of the ‘o’ channel selection.
Example: [VOLL1000]
In Matrix Mode set left volume for output 1 to a value of 0. In Direct
Mode set left volume for all outputs to a value of 0.
Note: see [MDVOL0] & [MDVOL1]
[OK]
VOLRoxxx
Set the output volume for only right channel of output ‘o’ to value ‘xxx’.
1 <= o <= 8; 000 <= xxx <= 255 decimal.
In Direct Mode the [VOLRoxxx] command controls all right outputs
simultaneously regardless of the ‘o’ channel selection.
Example: [VOL8255]
In Matrix Mode set right volume for output 8 to a value of 255. In Direct
Mode set right volume for all outputs to a value of 255.
Note: see [MDVOL0] & [MDVOL1]