Twisted pair cable termination – Extron Electronics MTP 15HD RS Series User Guide Rev. A User Manual

Page 17

Advertising
background image

As an alternative, an Extron PS 124 Universal 12 VDC Power Supply (part number
60-1022-01) can power multiple MTPs or other Extron 12 VDC devices using only one AC
power connector.

Twisted Pair Cable Termination

Figure 9 details the recommended termination of twisted pair cables with RJ-45 connectors
in accordance with the TIA/EIA T568A or TIA/EIA T568B wiring standards. You can use either
standard with CAT 5, 5e, and 6 cable, but ensure that you use the same standard on
both ends of the cable
.

RJ-45

Connector

Insert Twisted

Pair Wires

12345678

Pins:

Pin

Signal

1

Red/V. sync +

2

Red/V. sync -

3

Green +

4

Blue/H. sync +

5

Blue/H. sync -

6

Green -

7

RS-232 +

8

RS-232 -

Wire color

White-green

Green

White-orange

Blue

White-blue
Orange
White-brown

Brown

Wire color

TIA/EIA T 568 A TIA/EIA T 568 B

White-orange

Orange

White-green

Blue

White-blue
Green
White-brown

Brown

NOTE:

When using Enhanced Skew-Free

™

AV UTP cable, use the TIA/EIA T568A

standard only.

Figure 9.

Twisted Pair Cable Termination Diagram

NOTES:

•

RJ-45 termination with CAT 5, 5e, or 6 cable must comply with the
TIA/EIA T568A or TIA/EIA T568B wiring standards for all connections.

•

RJ-45 termination with Skew-Free AV UTP cable must comply with
TIA/EIA T568A only.

•

For proper grounding of shielded twisted pair cable, ensure the shield around
each wire pair are all tied to the RJ-45 connectors on both ends, in accordance with
the connector specifications provided by the manufacturer.

•

Extron Enhanced Skew-Free AV cable is not recommended for
Ethernet/LAN applications. This cable is specially designed for compatibility with
Extron Twisted Pair products that are wired using the TIA/EIA T568A standard.

•

The green, brown, and blue wire pairs of this cable have virtually identical lengths
and should be used to transmit the RGB signals.

•

The orange wire pair of this cable has a different length and should not be used to
transmit the RGB signals.

MTP 15HD RS Series • Installation and Operation

13

Advertising