Mlc 52 series quick start guide, cont’d, Step 3, Step 4 – Extron Electronics MLC 52 Series Quick Start Guide User Manual

Page 12: Mlc 52 series • quick start guide 10

Advertising
background image

MLC 52 Series Quick Start Guide, cont’d

MLC 52 Series • Quick Start Guide

10

1

1

2

3

4

E

ON

2 3 4

Tx

IR OUT

GND

IR IN

GND

+ 12V

1

1

2

3

4

E

ON

2 3 4

Tx

IR OUT

GND

IR IN

GND

+ 12V

Less Than 6”

IR Beaming

Transmitting MLC

Receiving MLC

1

ON

2 3 4

1

ON

2 3 4

Setting up donor and receiver units for wireless data transfer

The illustrations show the standard (1-gang sized) MLC 52. However, the
procedures are the same for the VC models.

Step 3

Leave all configuration switches set to Off

on the MLC that will

be transmitting the data.

Step 4

Set switch #2 to On and all other switches to Off

on the MLC that

will be receiving the data.

When the two units are placed in the proper position for data transmission, and the
receiving unit’s configuration switch #2 is set to On, the transmitting and receiving
units detect each other’s presence, and the data transfer begins automatically.

During data transfer, the front panel buttons act as progress indicators. The
buttons on both the transmitting and the receiving MLCs blink sequentially in
clockwise order, starting with the ON button in the upper-left corner (see the
diagram on the next page). This cycle repeats until transfer is complete.

Receiving MLC

1

ON

2 3 4

Transmitting MLC

1

ON

2 3 4