4-7

MediaLink Controllers • Serial Communication

IRCM-DV+ address 2, address 1 button association

Associate MLC buttons w/IRCM-DV+ 25*

X?

#

DVA_VMap*

X?

Associate specific MLC buttons
with the VCR and DVD halves
of the IRCM-DV+ which has
DIP switch-based addresses of 1
and 2.

Example:

25*52#

DVA_VMap*052

Associate MLC button 4 with
IRCM-DV+ address 1 (DVD
functions) and
MLC button 3 with IRCM-DV+
address 2 (VCR functions). See
the illustration.

Command/response table for special function SIS commands, continued

Command

ASCII Command Response

X?

values

(host to MLC)

(MLC to host)

and additional descriptions

Button to

associate the

VCR half

(even address,

2 or 4) with

Button to

associate the

DVD half

(odd address,

1 or 3) with

3

= (3 x 16) + (4) = 52

4

X?

The VCR half of the IRCM-DV+

will be associated with button 3.

The DVD half of the IRCM-DV+

will be associated with button 4.

1

2

3

4

5

6

IRCM-DV+ address 4, address 3 association

Associate MLC buttons w/IRCM-DV+ 26*

X?

#

DVB_VMap*

X?

Associate MLC buttons with the
VCR & DVD parts of an
IRCM-DV+ which has DIP
switch-set addresses of 3 and 4.

Miscellaneous settings

Automatic shut-off

15 *

X?

#

AutoOff*

X?

0 = disabled (use manual shutoff)

(Issue a display power-off

(default),

command after a specific

1 = 15 minute shutoff delay,

period of inactivity.)

2 = 30 minute delay,
... in 15 minute steps up to
32 = 480 minutes (8 hours).

Automatic on

27*

X?

#

AutoOn*

X?

0 = off: a power-on command is

(Send a display power-on

not sent when an MLC input

command when any MLC

selection button is pressed.

input selection button is pressed.)

1 = on: pressing an MLC input
selection button causes a
power-on command to be sent.

Set switch exclusion

20 *

X?

#

SwtMode*

X?

Set the (6 bit, binary) address
(0-63) of the MLC’s input selection
buttons that will not be used for
input switching.
Examples:

0 = all six buttons are included in
the switching rotation.
1 = exclude input selection button 1
(upper left).
32 = exclude input selection button 6
(lower right).
56 = exclude buttons 4-6.
63 = no buttons are included for
switching.

Set power-down button hold to off

22 *

X?

#

PwrOffDly*

X?

0 = the MLC requires a 2-second
delay (Display Power button
hold period) to start power-off
sequences (default).
1 = the MLC needs no delay (the
button hold period is 0).

Each of the MLC’s six input selection
buttons can be disabled for switching
between inputs. If the MLC does not
have a switcher slaved to it, and the
projector has only three inputs, for
example, you may wish to exclude
from the switching rotation the excess
input selection buttons (buttons 4-6).
Each excluded button can still have
an RS-232 or IR command or a relay
associated with it, but pressing an
excluded button will not cause any
input switching to occur.

The Display Power Off button’s two-
second press and hold period can be
changed, via HyperTerminal only, to
zero seconds.