Step 2: mount the enclosure to an equipment rack, Step 3: connect a/v and control cables, Step 4: connect power and test the system – Extron Electronics PowerCage 1600 Enclosure Setup Guide User Manual

Page 2: Contact information, Powercage 1600 enclosure • setup guide (continued), Some boards have mode switches, Board status leds

Advertising
background image

2

PowerCage 1600 Enclosure • Setup Guide (Continued)

Extron USA - West
Headquarters

+800.633.9876

Inside USA/Canada
Only

+1.714.491.1500
+1.714.491.1517
FAX

Extron USA - East

+800.633.9876

Inside USA/Canada
Only

+1.919.863.1794
+1.919.863.1797
FAX

Extron Europe

+800.3987.6673

Inside Europe Only

+31.33.453.4040
+31.33.453.4050
FAX

Extron Asia

+800.7339.8766

Inside Asia Only

+65.6383.4400
+65.6383.4664
FAX

Extron Japan

+81.3.3511.7655
+81.3.3511.7656
FAX

Extron China

+400.883.1568

Inside China Only

+86.21.3760.1568
+86.21.3760.1566
FAX

Extron Middle East

+971.4.2991800
+971.4.2991880
FAX

© 2010 Extron Electronics All rights reserved.

www.extron.com

Step 2: Mount the enclosure to an equipment rack.

Attach the included mounting brackets to the sides of the enclosure, then fasten the brackets to the rack. The brackets can
be attached at either the front or the back.

CAUTION: Leave open space of at least 1U on the top, bottom, and sides of the enclosure to allow adequate air

circulation and prevent overheating. Do not cover the vents or fans.

Step 3: Connect A/V and control cables.

Refer to the setup guides and user guides for the models of transmitter and receiver boards you are installing for details on
how to cable and set up each board.

z

z

Some fiber optic boards include pass-through RS-232 connections.

z

z

Some boards have mode switches.

z

z

Some MTP twisted pair boards include picture adjustment or peaking controls.

Step 4: Connect power and test the system.

a.

Connect power to the PowerCage enclosure and to the input and output devices.

b.

Verify that the PowerCage fans, boards, and LEDs power up correctly. The green Power LED should be lit for each
installed and securely seated power supply and fan. Press the Comm Select button and view the front panel: each time
you press the button, the Power LED that corresponds to the currently selected, installed transmitter or receiver board
should light.

c.

Ensure that A/V signals input to the boards are
output at the correct devices. If they are not,
correct cabling
and check
switch settings
(if applicable
for installed
models) on the
PowerCage
boards.

68-1717-50.
Rev.A
08.10

PowerCage 1600

COMM

1

POWER

ALARM

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

1

PSU

2

PSU

1

FAN

2

FAN

COMM

SELECT

CONFIG

TEMP

COMM

1

POWER

ALARM

1

PSU

1

FAN

Front Panel

Board status LEDs

for multi-function boards (up to 16 optional boards)

Power supply status LEDs

Fan status LEDs

System temperature status LED

Configuration port (RS-232)

Communication selection (Comm Select) button

Alarm LED — Lights when the receiving

(Rx) fiber link on a PowerCage FOX
board is broken or disconnected.
This feature depends on the model of
PowerCage board. This LED is not
used for PowerCage MTP boards.

Comm LED — Lights when the

corresponding board is selected
(see Comm Select button) and can
be communicated with via the front
panel Config port.

Power LED — Lights when the

corresponding board receives power.

Alarm LED — Lights when the

power supply malfunctions,
such as providing an overvoltage
(14 VDC or more) or
undervoltage (10.5 VDC or less).

Power LED — Lights when the

power supply receives power.

Alarm LED — Lights when the

corresponding fan malfunctions.

Power LED — Lights when the

corresponding fan receives power.

Press repeatedly as needed to select the board to connect to
the Config port. The Comm LED for the selected board lights.

Protocol varies by model.
Basic protocol for all boards:
9600 baud, 8 data bits, 1 stop bit, no parity

Pin configuration for this
tip-ring-sleeve connector:

If this LED lights, the unit is too hot; equipment
damage is imminent. Power down the unit,
ensure adequate ventilation, and allow the
PowerCage to cool before restoring power.

9-pin D Connection TRS Plug
Pin 2

PC's Rx line

Tip

Pin 3

PC's Tx line

Ring

Pin 5 PC signal ground Sleeve