Switcher control, Switcher control -9, 9 pvs 305sa switcher • installation – Extron Electronics PVS 305SA User Guide User Manual

Page 18: Config, Pvs 305sa rear panel, Control

Advertising
background image

2-9

PVS 305SA Switcher • Installation

Switcher control

i

Control port — The PVS switcher can be controlled via an RS -232 connection

directly from a host computer, a control system, or a MediaLink Controller.

For IR remote control connect an Extron IR Link to this port. RS-232

connection can be used to configure the PVS switcher. Connect a cable

between this port and an Extron MediaLink Controller or an optional IR Link

IR signal repeater.

•

The MLC provides remote control of input switching and volume.

The RS-232 protocol is

• 9600 baud • 8-bit • 1 stop bit • no parity • no flow control.

Refer to the MLC 104 IP Plus Series Reference Manual for full details.

•

The IR Link accepts modulated IR signals from a remote control (for

example, the Extron IR 452 remote) enabling the remote control to be used

for selecting the switcher inputs.

W

ire the captive screw connector and connect it to a computer or control

system, an MLC, or an IR Link, as shown in figures 2-10 through 2-12.

MLC 104 IP Plus front and side panels

2

3

G

R

O

U

N

D

1

IR

IN

G

R

O

U

N

D

IR

O

U

T

C

M

SC

P

GR

OU

ND

GR

OU

ND

Tx

R

x

DISPLAY

RS-232/IR

LAN

PRESS TAB WITH

TWEEKER TO REMOVE

A B

MLS PWR

RS-232 12V

DIGITAL

I/O

A B C D E

COMM LINK

+V

O

U

T

G

R

O

U

N

D

Tx

R

x

+1

2V

IN

CONFIG

DISPLAY

VOLUME

MLC 104 IP PLUS

ON

VCR

DVD

PC

OFF

1

2

3

4

CONTROL

A B C

PVS 305SA Switcher's
rear panel
Control port

NOTE

You must connect a ground

wire between the MLC and the

switcher.

MLC 104 IP Plus
MLS and power ports

NOTE

If you use cable that has a drain

wire, tie the drain wire to ground

at both ends.

D E

Tx Rx IR

+

12 V

RS-232 12V

MLS PWR

A B

Rx

Tx

GR

OUND

GR

OUND

+12V IN

Ground ( )

Transmit (Tx)

B Receive (Rx)

A

Transmit (Tx)

Receive (Rx)

B

A

+12 VDC input

50 feet (38 m) maximum

PVS 305SA Rear Panel

L

R

L

R

L

R

AUX AUDIO

INPUT 5

LINE OUT

VOICELIFT

RECEIVER

PAGING

SENSOR

DO NOT

GROUND

OR SHORT

SPEAKER

OUTPUTS

1B RGB

1A RGB

2B RGB

2A RGB

RGB

VIDEO

RGB

VIDEO

3A RGB

4A RGB

I

N
P
U
T
S

RS-232 MLC/IR

2/4/8

Ohms

CLASS 2 WIRING

AMPLIFIED AUDIO OUT

VOL/MUTE

Tx Rx IR

12V

10V

50mA

POWER

US

LISTED

17TT
AUDIO/VIDEO
APPARATUS

®

RGB

VIDEO

OUTPUTS

CONTROL

N15779

12V
5A MAX

RS-232

RS-232

and power

Projector

4B

3B

Figure 2-10 — Connecting an MLC 104 to the switcher

N

The PVS 305SA power supply can support a typical system, for example:

• a PVS 305SA

• 4 PVT Wallplates

• 2 or 4 speakers (see

“Speaker Configuration” in appendix B for details

)

• an MLC 104 IP Plus with an IRCM DV+

• VoiceLift microphone system

• If an SCP 104 is used in the system, the MLC 104 Plus MUST have its

own power supply.

• The PVS 305SA provides sufficient power to run an MLC 104 IP Plus or

MLC 226 IP model.

Advertising