Cable testing, Equalizing pair skew, Installation and operation, cont’d – Extron Electronics TP Receivers User Guide User Manual

Page 30

Advertising
background image

TP Receivers • Installation and Operation

Installation and Operation, cont’d

2-18

Cable testing

The TP units are designed for and perform best with Extron

Enhanced Skew-Free A/V cable terminated in accordance

with the TIA/EIA T 568 A wiring standard. CAT 5, Cat 5e and

Cat 6 cables are acceptable but less preferable. Extron also

recommends the use of pre-terminated and tested cables. Cables

terminated on site should be tested before use to ensure they

comply with Category 5/5e/6 specifications.

Equalizing pair skew

CAT 5/5e/6 TP cable can lead to registration errors between the

red, green, and blue video signals. Pair skew can be measured

with test equipment or identified by viewing a crosshatch test

pattern with a critical eye to determine if either the red, green,

or blue video image leads (appears to the left of) the other two

video images.

N

Unless the cable is replaced, the skew adjustment is only
done once during installation.

Try using the following methods to minimize or eliminate pair

skew:

•

Switch to Enhanced Skew-Free A/V UTP cable.

•

Add a skew compensation cable to the receiver

output equal to the length of pair skew.

•

Install an SEQ 100 15HD Skew Equalizer on the

video output of the receiver and adjust the skew for

the leading video image.

Advertising