2

Description

The Extron P/S 150 is a 15VDC 5.0 A universal power supply with
six separate outputs on two 6-connector, 3.5 mm captive screw
connectors. The outputs are rated at 15V, 800 mA each. The
universal power supply can power up to six Twisted Pair (TP)
receivers or as many Extron architectural products as possible
without exceeding the P/S 150’s 4.8 A current limit.

The rack mountable P/S 150 has an internal auto-switchable
power supply that can accept 100VAC to 240VAC at 50 Hz to 60 Hz.

Installation

For optional rack mounting, mount up to four P/S 150s on a 19"
1U Universal Rack Shelf (Extron P/N 60-190-01) (figure 1).

(2) 4-40 x 1/8" screws
Use 2 mounting holes
on opposite corners

Half-rack
false front panel
uses 2 front holes

Quarter-Rack
False Front Panel

P/S

15

0

15 V

DC P

OW

ER S

UPP

LY

Figure 1 — Rack mounting the P/S 150

1

.

Mount the P/S 150 on the rack shelf, using two 4-40 x 1/8
screws in opposite (diagonal) corners.

2

.

If necessary, mount the half-rack false front panel (included
with the Universal Rack Shelf) and/or the quarter-rack false
front panel (included with the P/S 150) to the shelf, using
two 4-40 x 1/8 screws in the front holes for each panel.

Rear Panel Connections

1

Connect the power cables from the various devices that
will receive power from the P/S 150 to the 3.5 mm captive
screw connectors (included) (figure 2).

50/60 Hz 2.2 A MAX

1

100-240V -

CHANNEL OVERLOAD

POWER-GREEN

OVERLOAD-AMBER

15 VDC OUTPUT 800 mA PER CHANNEL

1

2

3

4

5

6

2

1

4

P/S 150

15 VDC POWER SUPPLY

3

5

Figure 2 — P/S 150 front and rear panels

Each captive screw connector has six poles and can support
up to three power supply outputs (figure 3).

1

2

3

4

5

– wire

+ wire

– wire

Up to 3 power
supply outputs
per connector

+ wire

Figure 3 — Connecting power cables to P/S 150

2

Connect the P/S 150 to an AC power source.

Operation

The minimum load for operation is 100 mA.

3

Power LED

— This front panel LED (figure 3) lights to

indicate that the P/S 150 is receiving power.

4

Power/Overload LED

— This rear panel LED lights green

when power is applied and is normal, and lights amber
when power is applied and an overcurrent condition (4.8
amps or more) exists.

CAUTION

Continued operation in an overload condition will
cause premature power supply failure.