AII-AWI-8

AII 8AR (150 A21)

(1) 150A LAMP, 2780 RATED LUMENS, 1.2 S/MH, TEST NO. LTL7618

AII 8AR (200 A23)

(1) 200A LAMP, 3930 RATED LUMENS, 1.1 S/MH, TEST NO. LTL8058

AII 8AR GL (150 A21)

(1) 150A LAMP, 2780 RATED LUMENS, 1.2 S/MH, TEST NO. LTL7760

PH

OTO
M

ET

RY

Distribution Curve

Distribution Data

Output Data

Coefficient of Utilization

Illuminance: Single Luminaire 30” Above Floor

AII/AWI

20.3cm (8”) Open/Wallwash Reflector

PHOTOMETRY NOTES

Tested to current IES and NEMA standards under stabilized laboratory conditions.

Actual performance may differ as a result of end-user environment and application.

Consult factory or IES file for microgroove baffle, black cone or other photometric reports.

AII 8AR GL (200 A23)

(1) 200A LAMP, 3930 RATED LUMENS, 1.1 S/MH, TEST NO. LTL8091

20°

40°

60°

80°

90°

180°

300

600

900

1200

1500

%

0

2

f

p

pc

80%

70%

50%

pw

50% 30% 10%

50% 30% 10%

50% 30% 10%

82

76

71

66

61

57

54

50

47

44

42

82

74

68

62

57

53

49

46

43

40

37

82

73

66

60

55

50

46

43

40

37

35

80

75

70

65

61

57

53

50

47

44

41

80

73

67

62

57

53

49

46

43

40

37

80

72

65

59

54

50

46

43

40

37

35

76

72

67

63

59

55

52

49

46

43

41

76

71

65

60

56

52

48

45

42

40

37

76

69

63

58

54

49

46

43

40

37

35

0

1

2

3

4

5

6

7

8

9

10

Zone

Lumens % Lamp

0° - 30°

0° - 40°

0° - 60°

0° - 90°

90° - 180°

0° - 180°

1344

1868

1959

1959

0

1959

47.2

65.6

68.7

68.7

0.0

68.7

Ave

Lumens

15°

25°

35°

45°

55°

65°

75°

85°

90

1574

1616

1678

1586

874

80

2

0

0

0

0

155

475

715

524

87

3

0

0

0

52.0

28.0

17.4

11.9

8.6

6.6

9.0

11.4

13.8

16.2

26.0

14.0

8.7

5.9

4.3

9.2

12.6

15.9

19.3

22.7

5.2

2.8

1.7

1.2

0.9

50% beam

61.9°

10% beam

80.0°

Mounting

Height

Inital FC

Center

Beam Diameter FC Diameter FC

8.0

10.0

12.0

14.0

16.0

20°

40°

60°

80°

90°

180°

500

1000

1500

2000

2500

%

0

2

f

p

pc

80%

70%

50%

pw

50% 30% 10%

50% 30% 10%

50% 30% 10%

84

78

73

68

64

60

56

52

49

47

44

84

77

70

65

60

56

52

48

45

42

40

84

75

68

62

57

52

49

45

42

40

37

82

77

72

67

63

59

55

52

49

46

44

82

75

69

64

59

55

51

48

45

42

40

82

74

67

61

56

52

49

45

42

40

37

78

74

69

65

61

58

54

51

48

46

43

78

73

67

63

58

54

51

48

45

42

39

78

72

66

60

56

52

48

45

42

39

37

0

1

2

3

4

5

6

7

8

9

10

Zone

Lumens % Lamp

0° - 30°

0° - 40°

0° - 60°

0° - 90°

90° - 180°

0° - 180°

2023

2663

2775

2776

0

2776

51.5

67.8

70.6

70.6

0.0

70.6

Ave

Lumens

15°

25°

35°

45°

55°

65°

75°

85°

90

2895

2845

2502

2346

1001

96

7

0

0

0

0

266

713

1043

640

104

8

1

0

0

95.7

51.5

32.1

21.9

15.9

5.8

8.0

10.1

12.2

14.4

47.9

25.7

16.0

10.9

7.9

8.6

11.7

14.9

18.0

21.1

9.6

5.1

3.2

2.2

1.6

50% beam

56.0°

10% beam

76.1°

Mounting

Height

Inital FC

Center

Beam Diameter FC Diameter FC

8.0

10.0

12.0

14.0

16.0

20°

40°

60°

80°

90°

180°

300

600

900

1200

%

0

2

f

p

pc

80%

70%

50%

pw

50% 30% 10%

50% 30% 10%

50% 30% 10%

75

70

65

61

56

53

49

46

43

41

38

75

68

62

57

53

49

45

42

39

37

34

75

67

60

55

50

46

43

39

37

34

32

74

69

64

60

56

52

49

46

43

40

38

74

67

62

57

52

49

45

42

39

37

34

74

66

60

54

50

46

42

39

37

34

32

70

66

62

58

54

51

48

45

42

40

37

70

65

60

56

52

48

45

42

39

36

34

70

64

58

54

49

46

42

39

36

34

32

0

1

2

3

4

5

6

7

8

9

10

Zone

Lumens % Lamp

0° - 30°

0° - 40°

0° - 60°

0° - 90°

90° - 180°

0° - 180°

1206

1676

1758

1758

0

1758

43.4

60.3

63.2

63.2

0.0

63.2

Ave

Lumens

15°

25°

35°

45°

55°

65°

75°

85°

90

1412

1450

1506

1423

784

72

2

0

0

0

0

139

426

641

470

78

3

0

0

0

46.7

25.1

15.6

10.7

7.7

6.6

9.0

11.4

13.8

16.2

23.3

12.5

7.8

5.3

3.9

9.2

12.6

15.9

19.3

22.7

4.7

2.5

1.6

1.1

0.8

50% beam

61.9°

10% beam

80.0°

Mounting

Height

Inital FC

Center

Beam Diameter FC Diameter FC

8.0

10.0

12.0

14.0

16.0

20°

40°

60°

80°

90°

180°

500

1000

1500

2000

2500

%

0

2

f

p

pc

80%

70%

50%

pw

50% 30% 10%

50% 30% 10%

50% 30% 10%

77

72

67

63

59

55

51

48

45

43

40

77

70

65

59

55

51

48

44

42

39

37

77

69

62

57

52

48

45

42

39

36

34

76

71

66

62

58

54

51

48

45

43

40

76

69

64

59

55

51

47

44

41

39

37

76

68

62

56

52

48

45

42

39

36

34

72

68

64

60

56

53

50

47

44

42

40

72

67

62

58

54

50

47

44

41

39

36

72

66

60

56

51

48

44

41

39

36

34

0

1

2

3

4

5

6

7

8

9

10

Zone

Lumens % Lamp

0° - 30°

0° - 40°

0° - 60°

0° - 90°

90° - 180°

0° - 180°

1861

2450

2553

2554

0

2554

47.3

62.3

65.0

65.0

0.0

65.0

Ave

Lumens

15°

25°

35°

45°

55°

65°

75°

85°

90

2663

2617

2302

2158

921

88

6

0

0

0

0

245

656

960

589

96

8

1

0

0

88.0

47.3

29.5

20.1

14.6

5.8

8.0

10.1

12.2

14.4

44.0

23.7

14.8

10.1

7.3

8.6

11.7

14.9

18.0

21.1

8.8

4.7

2.9

2.0

1.5

50% beam

56.0°

10% beam

76.1°

Mounting

Height

Inital FC

Center

Beam Diameter FC Diameter FC

8.0

10.0

12.0

14.0

16.0

Advertising