Gotham 10 PDPF High Elevations Candéo SpecSheet User Manual

Page 2

Advertising
background image

GOTHAM ARCHITECTURAL DOWNLIGHTING | 1400 Lester Road Conyers GA 30012 | P 800.315.4982 | gothamlighting.com

© 2008-2012 Acuity Brands Lighting, Inc. All Rights Reserved. Rev. 09/09/13. Specifications subject to change without notice.

PAGE 2 OF 4

PDPF-10-CAnDEO

10” PDPF
High Elevations

®

Performance Downlight Candéo

®

Pendant, Horizontal Triple-Tube Lamp

PH

OTO
M

ET

RY

All dimensions are inches (centimeters) unless otherwise noted.

Aperture:

9-3/4 (24.8)

Overall Diameter:

11-3/8 (28.9)

Height:

19-3/8 (49.2)

ENERGY (Calculated in accordance with NEMA standard LE-5A)

Annual*

LER. Energy

Lamp

Ballast

Input

DVH Cost

Lamps

Lumens Factor

Watts

37

$6.48

(2) 32W TRT

4800

0.96

69

34

$7.03

(2) 42W TRT

6400

0.95

94

30

$8.08

(3) 42W TRT

9600

1.00

139

*Comparative yearly lighting energy cost per 1000 lumens

ORDERING NOTES

1.

Available in 1 or 2 lamp only.

2.

Multi-volt electronic ballast capable of operating on any line voltage from
120V through 277V, 50 or 60Hz.

3.

Additional architectural colors available; see

www.lithonia.com/archcolors

.

4.

Available with CYS or CRS stem option only.

5.

Provided with 10ft. aircraft cable and black cord. White cord standard when
white pendant is ordered. Consult factory for additional lengths.

6.

For use with pendant mount (PM) units only. Length of stem must be specified
(from 12” to 48” in 2” even increments). EX: CYS12. Stems greater than 48”,
up to 240”, provided with couplers. Consult factory for exterior use.

7.

For additional ballast types, refer to

TECH-250

.

8.

Not available with ACC mounting.

9.

Available in 120V or 277V only.

10. Not available with 57TRT.
11. Standard on 3-lamp fixtures. Stem required for DMHL and S5 HW.
12. Not available with MVOLT. Must specify voltage.

DIM

EN

SIO

N

AL D
AT

A

EL

EC

TR

IC

AL

N

OT

ES