III. Handling and Storage

The FastVac system is shipped on a skid, securely crated, with
all openings sealed at the factory. It may be stored in this manner,
under cover. Use accepted rigging practices to move the system
for storage or installation.

Unpacking
Unpack the machine from the shipping crate and skid. (The
stationary model should be unpacked in its permanent location
to simplify handling.)

NOTE: Inspect the machine for damage and report any shipping
damage to the carrier. If there is any other damage, contact
your Spencer Representative.

NOTE: Small parts or accessories may have been shipped in
the dirt can. This is a standard shipping procedure to keep
orders organized. Lower the dirt can by lifting the bail and
remove any loose parts inside.

IV. Installation

Location
This equipment is designed for operation at or near sea level
atmospheric pressure and a nominal ambient temperature of
70°F (21°C). The ambient temperature should not exceed 104°
F (40° C). The area of use should have adequate ventilation to
disperse warm exhaust air from the vacuum producer. Contact
your Spencer Representative if your conditions differ.

3

Single-Phase

Single Voltage

5

1

4

8

Line

NOTES:

(1) For three-phase, interchange any two line connections to reverse shaft rotation
(2) For single-phase, interchange motor leads 5 and 8 to reverse shaft rotation

MOTOR WIRING

Three-Phase

Low Voltage

High Voltage

Single-Phase

Low Voltage

High Voltage

Line

Line

Line

Line

Stationary Model. Position the machine on a level concrete floor,
concrete pad or any other substantial floor, over the four furnished
vibration isolation pads. Be sure the machine can be reached for
servicing and that the dirt can is accessible for emptying.

Mobile Model. Any flat, dry, level surface is suitable. As a safety
precaution, set the caster brakes to prevent accidental movement.

Options and Accessories
Many original equipment options and accessory components
are available from Spencer to configure a vacuum cleaning
system as desired or to adapt a system for specific applications.
• Metal tubing and fittings
• HEPA disposable, high-efficiency filters
• Motor starters (for stationary models)
• Cleaning hoses, wands, tools and accessories
• Vacuum inlet valves

FastVac Setup
Stationary Model.
System installation requires a disconnect,
starter, electrical service and a vacuum tubing system. Position the
machine in its permanent location for operation. Wire the motor
starter or control panel to the Vortex vacuum producer motor.

Electrical Wiring
Motor Data—Typical Values, 60 Hz Operation

Three-Phase

Single-Phase

Model No.

VB-037

VB-055

VB-037S

Power (hp)

5

7.5

5

Voltage (V)

200-230/460

230

FL Amp (A)

13.2-12/6

19.8-17.2/8.6

20.8

Voltage (V)

575

575

FL Amp (A)

4.8

7