Anti-cavitation pressure reducing valve, 01ko, Model – Cla-Val 90-01KO User Manual

Page 5

Advertising
background image

Anti-Cavitation
Pressure Reducing Valve

High Pressure

Isolation Valve

Gauge

Constant
Downstream
Pressure

CLA-VAL 90-01BYKO

Pressure Reducing Valve

CLA-VAL 90-01ASKO

Pressure Reducing Valve

CLA-VAL Model

90-01KO

Anti-Cavitation Trim

for Excess Pressure Drop

Consult Cavitation Chart

Isolation Valve

Gauge

Constant
Downstream
Pressure

High Pressure

The "D" check feature on a vertically installed 6" and larger valves must be horizontally installed.

Typical Applications

Typical applications include pressure reducing valve station
using Model 90-01BYKO and Model 90-01ASKO in parallel to
handle wide range of flow rates. Larger Model 90-01BYKO valve
meets requirements of peak loads and smaller Model
90-01ASKO handles low flows.

Schematic Diagram

Item Description

1

Hytrol (100-01KO Main Valve)

2

X58 Restriction Fitting

3

CRD Pressure Reducing Control

Optional Features

Item Description

A

X46A Flow Clean Strainer

B

CK2 (Isolation Valve)

C

CV Flow Control (Closing)*

D

Check Valves with Isolation Valve

P

X141 Pressure Gauge

S

CV Speed Control (Opening)

V

X101 Valve Position Indicator

Y

X43 "Y" Strainer

*

The closing speed control (optional) on this valve should

always be open at least three (3) turns off its seat.

•

Virtually Cavitation Free Operation

•

Sensitive and Accurate Pressure Control

•

Easy Adjustment and Maintenance

•

Tamper Resistant

•

Optional Check Feature

•

Fully Supported Frictionless Diaphragm

The Cla-Val Model 90-01KO Anti-Cavitation Hytrol Pressure Reducing
Valve automatically reduces a higher inlet pressure to a steady lower down-
stream pressure, regardless of changing flow rate and/or varying inlet pres-
sure. This valve is an accurate, pilot-operated regulator capable of holding
downstream pressure to a pre-determined limit. When downstream pres-
sure exceeds the pressure setting of the control pilot, the main valve and
pilot valve close drip-tight.

If a check feature is added, and a pressure reversal occurs, the down-
stream pressure is admitted in the main valve cover chamber, closing the
valve to prevent return flow.

Cla-Val Model

90-01KO

Pressure Reducing Valve with Anti-Cavi-

tation Trim provides for optimum downstream pressure control
while reducing noise and eliminating damage associated with cav-
itation.
See Cavitation Guide to determine if the valve is a candidate for
the KO Anti-Cavitation Trim.

90-01KO

MODEL

(Full Internal Port)

Advertising