Wiring instructions – Cla-Val X143IP User Manual
Page 2

Max 250
VAC
+12 VDC
- 0 VDC
- 0 VDC
+24 VDC
contact
relay
1
2
3
4
5
6
12 VDC
24 VDC
Wiring Instructions
IMPORTANT SAFETY PRECAUTION
Before making any wiring connections in the electrical box,
please take the following precautions:
• Ensure that the isolation valve on the bypass is closed
so that the turbine cannot be engaged
• Confirm that the battery is disconnected
• Confirm that the LED on the PCB is not blinking
• Terminal 1: +12 VDC; Terminal 2: 0V
• Terminal 3: +24 VDC; Terminal 4: 0V
• Terminal 5 and Terminal 6: Alarm battery (dry contact relay closure)
Figure 3:
The removable terminal strip with
Terminals 1 - 10 makes
connections easier
Figure 1: X143IP
Figure 2: Terminal Connections
X143IP Intermediate Power Generator
Quick Start Instructions
2
Make electrical
connections as shown
in Figure 2.