Gorman-Rupp Pumps 82E1-L100EE-X 1215875 thru 1518663 User Manual

Page 7

Advertising
background image

80 SERIES

OM−05132

PAGE A − 2

SAFETY

Do not remove plates, covers, gauges,
pipe plugs, or fittings from an over-
heated pump. Vapor pressure within the
pump can cause parts being disen-
gaged to be ejected with great force.
Allow the pump to completely cool be-
fore servicing.

Overheated pumps can cause severe
burns and injuries. if overheating of the
pump occurs:

1. Stop the pump immediately.
2. Ventilate the area.
3. Allow the pump to completely cool.
4. Check the temperature before

opening any covers, plates,
gauges, or plugs.

5. Vent the pump slowly and cau-

tiously.

6. Refer to instructions in this manual

before restarting the pump.

Do not operate an internal combustion
engine in an explosive atmosphere.
When operating internal combustion
engines in an enclosed area, make cer-
tain that exhaust fumes are piped to the
outside. These fumes contain carbon
monoxide, a deadly gas that is color-
less, tasteless, and odorless.

Fuel used by internal combustion
engines presents an extreme explosion
and fire hazard. Make certain that all
fuel lines are securely connected and
free of leaks. Never refuel a hot or run-
ning engine. Avoid overfilling the fuel
tank. Always use the correct type of fuel.

If this pump is used with volatile and/or
flammable liquids, be certain proper
safety practices are followed before op-
erating or servicing the pump. Provide
adequate ventilation, prohibit smoking,
wear static-resistant clothing and
shoes. Clean up all fuel spills immedi-
ately after occurrence.

Never tamper with the governor to gain
more power. The governor establishes
safe operating limits that should not be
exceeded. The maximum continuous
operating speed for this pump is 3600
rpm.

Pumps and related equipment must be in-
stalled and operated according to all na-
tional, local and industry standards.