Pump and seal disassembly and reassembly – Gorman-Rupp Pumps 82E1-L100EE-X 1518664 and up User Manual

Page 24

Advertising
background image

OM-05132

80 SERIES

MAINTENANCE & REPAIR

PAGE E - 6

PUMP AND SEAL DISASSEMBLY
AND REASSEMBLY

Review all SAFETY information in Section A.

Follow the instructions on all tags, label and de­
cals attached to the pump.

This pump requires little service due to its rugged,
minimum‐maintenance design. However, if it be­
comes necessary to inspect or replace the wearing
parts, follow these instructions which are keyed to
the sectional views (see Figures 1 and 2) and the
accompanying parts lists.

This manual will alert personnel to known proce­
dures which require special attention, to those
which could damage equipment, and to those
which could be dangerous to personnel. However,
this manual cannot possibly anticipate and provide
detailed precautions for every situation that might
occur during maintenance of the unit. Therefore, it
is the responsibility of the owner/maintenance per­
sonnel to ensure that only safe, established main­
tenance procedures are used, and that any proce­
dures not addressed in this manual are performed
only after establishing that neither personal safety
nor pump integrity are compromised by such prac­
tices.

Before attempting to service the pump, shut down
the engine and take precautions to ensure that it
will remain inoperative. Close all valves in the suc­
tion and discharge lines.

For engine disassembly and repair, consult the lit­
erature supplied with the engine, or contact your
local engine representative.

Before attempting to open or service the
pump:

1. Familiarize yourself with this man­

ual.

2. Shut down the engine and take

precautions to ensure that the
pump will remain inoperative.

3. Allow the pump to completely cool

if overheated.

4. Check the temperature before

opening any covers, plates, or
plugs.

5. Close the suction and discharge

valves.

6. Vent the pump slowly and cau­

tiously.

7. Drain the pump.

If this pump is used with volatile and/or
flammable liquids, be certain proper
safety practices are followed before op­
erating or servicing the pump. Provide
adequate ventilation, prohibit smoking,
wear static‐resistant clothing and
shoes. Clean up all fuel spills immedi­
ately after occurrence.

Suction Check Valve Disassembly

(Figure 2)

Before attempting to service the pump, remove the
pump casing drain plug (19) and drain the pump.
Clean and reinstall the drain plug.

To service the suction check valve (25), remove the
suction piping. Remove the nuts (23) securing the
suction flange (24) to the pump casing (1). Pull the
check valve assembly from the suction port.

Inspect the check valve parts for wear or damage.
If replacement is required, remove the hardware
(26 and 27) and separate the check valve gasket
(20) and weights (28 and 30).

If no further disassembly is required, see Suction
Check Valve Installation
.

Pump Casing Removal

(Figure 1)

To service the impeller or seal assembly, discon­
nect the discharge piping. See Figure 1 and re­
move the hardware (23, 24, 25 and 26) securing
the pump casing to the base (13).

Advertising