Pump maintenance and repair - section e – Gorman-Rupp Pumps 83A1-L100EE-X 1215876 thru 1512372 User Manual

Page 19

Advertising
background image

80 SERIES

OM−05133

MAINTENANCE & REPAIR

PAGE E − 1

PUMP MAINTENANCE AND REPAIR - SECTION E

MAINTENANCE AND REPAIR OF THE WEARING PARTS OF THE PUMP WILL MAINTAIN PEAK
OPERATING PERFORMANCE.

STANDARD PERFORMANCE FOR PUMP MODEL 83A1−L100EE−X

Based on 70_ F (21_ C) clear water (corrected to

.80 specific gravity) at sea level with minimum suc-
tion lift. Since pump installations are seldom identi-
cal, your performance may be different due to such
factors as viscosity, specific gravity, elevation, tem-
perature, and impeller trim.

If your pump serial number is followed by an N",
your pump is NOT a standard production model.

Contact the Gorman-Rupp Company to verify per-
formance or part numbers.

Pump speed and operating condition
points must be within the continuous per-
formance range shown on the curve.

Advertising