Gorman-Rupp Pumps 82D1-EX13-X 1390156 and up User Manual
Page 30

80 SERIES
OM−06106
MAINTENANCE & REPAIR
PAGE E − 12
LUBRICATION
Seal Assembly
The seal is lubricated by the medium being
pumped. No additional lubrication is required.
Engine
Consult the literature supplied with the engine, or
contact your local engine representative.
ENGINE MODIFICATIONS
The engine used on this pump is not a standard
commercial model. It has been specially modified
by Gorman-Rupp for pumping gasoline and other
petroleum products in a well ventilated, non-flam-
mable atmosphere, free of combustible hazards.
The ground strap, shield and spark arresting modi-
fications to the engine must be maintained when-
ever the unit is serviced or replaced; otherwise, fire
or explosion could occur. Further modifications to
the engine may not be made without jeopardizing
the integrity of these safety features.