PUMP AND SEAL DISASSEMBLY
AND REASSEMBLY

Review all SAFETY information in Section A.

Follow the instructions on all tags, label and de-
cals attached to the pump.

This pump requires little service due to its rugged,
minimum-maintenance design. However, if it be-
comes necessary to inspect or replace the wearing
parts, follow these instructions which are keyed to
the Sectional Views (see Figures 1 through and 10)
and the corresponding Parts Lists. Maintenance
and repair instructions for the engine is covered
separately in the specific literature supplied by the
manufacturer.

This manual will alert personnel to known proce-
dures which require special attention, to those
which could damage equipment, and to those
which could be dangerous to personnel. However,
this manual cannot possibly anticipate and provide
detailed precautions for every situation that might
occur during maintenance of the unit. Therefore, it
is the responsibility of the owner/maintenance per-
sonnel to ensure that only safe, established main-
tenance procedures are used, and that any proce-
dures not addressed in this manual are performed
only after establishing that neither personal safety
nor pump integrity are compromised by such prac-
tices.

No instructions for removal and/or disassembly of
the enclosure or its components are provided in
this manual. If removal of the enclosure is required
for pump service, be sure to use safe shop practic-
es so as not to endanger personnel and use cau-
tion to prevent damage to the enclosure.

Many pump service functions may be performed
without separating the pump end assembly from
the engine. However, the priming chamber assem-
bly and discharge check valve assembly must be
removed to service most pump components. The
following instructions assume complete disassem-
bly of the pump is required.

Before attempting to service the pump, shut down
the engine and take precautions to ensure that it
will remain inoperative. Close all valves in the suc-
tion and discharge lines and drain the pump cas-
ing.

This manual will alert personnel to
known procedures which require spe-
cial attention, to those which could
damage equipment, and to those which
could be dangerous to personnel.

How-

ever, this manual cannot possibly antici-
pate and provide detailed instructions
and precautions for every situation that
might occur during maintenance of the
unit. Therefore, it is the responsibility of
the owner/maintenance personnel to
ensure that only safe, established main-
tenance procedures are used, and that
any procedures not addressed in this
manual are performed only after estab-
lishing that neither personal safety nor
pump integrity are compromised by
such practices.

Before attempting to open or service the
pump:

1. Familiarize yourself with this man-

ual.

2. Shut down the engine, disconnect

the positive battery cable and take
precautions to ensure that the
pump will remain inoperative.

3. Allow the pump to completely cool

if overheated.

4. Check the temperature and make

sure it is cool before opening any
covers, plates, gauges, or plugs.

5. Close the suction and discharge

valves.

6. Vent the pump slowly and cau-

tiously.

7. Drain the pump.

This pump may be used to handle mate-
rials which could cause illness through

Advertising