Gorman-Rupp Pumps V6A60-4045T 1456487 and up User Manual

Page 45

Advertising
background image

OM−06294

ULTRA V SERIES

MAINTENANCE & REPAIR

PAGE E − 19

SEAL PLATE

O-RINGS

IMPELLER

SHAFT

STATIONARY

SEAT

STATIONARY

ELEMENT

ROTATING

ELEMENT

DRIVE BAND

BELLOWS

IMPELLER

SHIMS

IMPELLER

SPRING

RETAINER

INTEGRAL

SHAFT

SLEEVE

SLEEVE

O-RING

SPRING

CENTERING

WASHER

SHEAR

RING

(SHEARED)

Figure 9. Cartridge Seal Assembly

This seal is not designed for operation at
temperatures above 160

_

F (71

_

C). Do not

use at higher operating temperatures.

If the seal plate (4) was removed, install the seal
plate O-ring (31) and lubricate it with light grease.
Install the seal plate gasket (5). Position the seal
plate over the shaft and secure it to the bearing
housing with the hardware (7 and 8). Install the
bearing housing O-ring (32) and lubricate it with
light grease.

To prevent damaging the shaft sleeve O-ring (29)
on the shaft threads, cover the threads with electri-
cal or duct tape. Slide the O-ring over the shaft until
it seats against the shaft shoulder. Remove the
tape covering the threads. Check to ensure that
the shaft threads are free of any tape residue and

clean as required before proceeding with seal
installation.

When installing a new cartridge seal assembly,
remove the seal from the container, and remove
the mylar storage tabs, if so equipped, from be-
tween the seal faces.

New cartridge seal assemblies may be
equipped with mylar storage tabs between
the seal faces. If so equipped, these stor-
age tabs must be removed before install-
ing the seal.

Lubricate the external stationary seat O-ring with
light oil. Slide the seal assembly onto the shaft until
the external stationary seat O-ring engages the
bore in the seal plate.

Clean and inspect the impeller as described in Im-
peller Installation and Adjustment. Install the full

Advertising