Gorman-Rupp Pumps T8A60S-F6L 1278434 thru 1318430 User Manual

Page 48

Advertising
background image

OM−05517

SUPER T SERIES

MAINTENANCE & REPAIR

PAGE E − 19

Slide the rotating portion of the seal (consisting of
the integral shaft sleeve, spring centering washer,
spring, bellows and retainer, and rotating element)
onto the shaft until the seal faces contact.

Proceed with Impeller Installation and Adjust-
ment.

Impeller Installation

(Figure 4)

Inspect the impeller, and replace it if cracked or
badly worn. Inspect the impeller and shaft threads
for dirt or damage, and clean or dress the threads
as required.

The shaft and impeller threads must be
completely clean before reinstalling the im-
peller. Even the slightest amount of dirt on
the threads can cause the impeller to seize
to the shaft, making future removal difficult
or impossible without damage to the im-
peller or shaft.

Install the same thickness of impeller adjusting
shims (29) as previously removed. Apply ‘Never-
Seez’ or equivalent to the shaft threads and screw
the impeller onto the shaft until tight. Be sure the
seal spring seats squarely on the back side of the
impeller.

NOTE

At the slightest sign of binding, immediately back
the impeller off, and check the threads for dirt. Do
not try to force the impeller onto the shaft.

A clearance of .025 to .040 inch (0,64 to 1,02 mm)
between the impeller and the seal plate is recom-
mended for maximum pump efficiency. Measure
this clearance, and add or remove impeller adjust-
ing shims as required.

NOTE

If the rotating assembly has been installed in the
pump casing, this clearance may be measured by
reaching through the priming port with a feeler
gauge.

Rotating Assembly Installation

(Figure 3)

Install the bearing housing and seal plate O-rings
(19 and 20), and lubricate them with light grease.
Ease the rotating assembly into the pump casing.
Be careful not to damage the O-rings.

Install the pump casing ring (14), and secure it to
the rotating assembly with the inner hardware (17
and 18).

NOTE

The inner capscrews are 1/4 inch (3,2 mm) shorter
than the outer capscrews.

Install the rotating assembly adjusting shims (12)
under the pump casing ring using the same thick-
ness as previously removed. Secure the ring to the
pump casing with the outer hardware (15 and 16).

To set the impeller and wear plate clearance refer
to the Back Cover Installation And Adjustment.

Suction Check Valve Installation

(Figure 3)

Inspect the check valve assembly (47) and replace
it if badly worn.

NOTE

The check valve assembly must be replaced as a
complete unit. Individual parts are not sold sepa-
rately.

Reach through the back cover opening with the
check valve and position the check valve adaptor
in the mounting slot in the suction flange (46). Align
the adaptor with the flange hole, and secure the as-
sembly with the check valve pin (3).

NOTE

If the suction or discharge flanges were removed,
replace the respective gaskets, apply ‘Permatex
Aviation No. 3 Form-A-Gasket’ or equivalent com-
pound to the mating surfaces, and secure them to
the pump casing with the attaching hardware.

Back Cover Installation And Adjustment

(Figures 3 and 12)

If the wear plate (21) was removed for replace-
ment, carefully center it on the back cover and se-

Advertising