Operation – Gorman-Rupp Pumps 86A2-F4L 1242877 thru 1322537 User Manual

Page 13

Advertising
background image

OM--00957

80 SERIES

OPERATION

PAGE C -- 1

OPERATION --- SECTION C

Review all SAFETY information in Section A.

Follow the instructions on all tags, labels and
decals attached to the pump.

Do not operate an internal combustion

engine in an explosive atmosphere.

When operating internal combustion

engines in an enclosed area, make cer-

tain that exhaust fumes are piped to the

outside. These fumes contain carbon

monoxide, a deadly gas that is color-

less, tasteless, and odorless.

This pump is designed to handle most

non-volatile, non-flammable liquids

containing specified entrained solids.

Do not attempt to pump volatile, corro-

sive, or flammable materials, or any liq-

uids which may damage the pump or en-

danger personnel as a result of pump

failure.

Never tamper with the governor to gain

more power. The governor establishes

safe operating limits that should not be

exceeded. The maximum continuous

operating speed for this pump is 2100

RPM.

PRIMING

Install the pump and piping as described in

IN-

STALLATION. Make sure that the piping connec-
tions are tight, and that the pump is securely
mounted. Check that the pump is properly lubri-

cated (see

LUBRICATION in MAINTENANCE

AND REPAIR).

This pump is self priming, but the pump should
never be operated unless there is liquid in the
pump casing.

Never operate this pump unless there is

liquid in the pump casing. The pump will

not prime when dry. Extended operation of

a dry pump will destroy the seal assembly.

Add liquid to the pump casing when:

1. The pump is being put into service for the

first time.

2. The pump has not been used for a consider-

able length of time.

3. The liquid in the pump casing has evapo-

rated.

When installed in a flooded suction application,
simply open the system valves and permit the in-
coming liquid to evacuate the air. After the pump
and piping system have completely filled, evacu-
ate any remaining air pockets in the pump or suc-
tion line by loosening pipe plug or opening bleeder
valves.

Once the pump casing has been filled, the pump
will prime and reprime as necessary.

After filling the pump casing, reinstall
and tighten the fill plug. Do not attempt
to operate the pump unless all connect-
ing piping is securely installed. Other-
wise, liquid in the pump forced out un-
der pressure could cause injury to per-
sonnel.

To fill the pump, remove the pump casing fill cover
or fill plug in the top of the casing, and add clean

Advertising