Gorman-Rupp Pumps 86A2-F3L 1330589 and up User Manual

Page 12

Advertising
background image

80 SERIES

OM−00955

PAGE B − 5

INSTALLATION

friction losses. Never install a throttling valve in a
suction line.

With high discharge heads, it is recommended that
a throttling valve and a system check valve be in-
stalled in the discharge line to protect the pump
from excessive shock pressure and reverse rota-
tion when it is stopped.

If the application involves a high discharge
head, gradually close the discharge
throttling valve before stopping the pump.

Bypass Lines

If a system check valve is used due to high dis-
charge head, it may be necessary to vent trapped
air from the top of the pump during the priming
process. This may be accomplished by installing a
bypass line from the top of the pump, back to the
source of liquid. The end of the bypass line must be
submerged. The line must be large enough to pre-
vent clogging, but not so large as to affect pump
discharge capacity.

ALIGNMENT

The alignment of the pump and engine are critical
for trouble-free performance. See Section E, Se-
curing Intermediate And Drive Assembly To En-
gine in MAINTENANCE AND REPAIR, for details.

Advertising