Lubrication – Gorman-Rupp Pumps 83A2-GX270 1423221 and up User Manual

Page 28

Advertising
background image

OM−06218

80 SERIES

MAINTENANCE & REPAIR

PAGE E − 10

Install the suction and discharge lines and open all
valves. Make certain that all piping connections are
tight, properly supported and secure.

Be sure the pump and engine have been properly
lubricated, see LUBRICATION.

Fill the pump casing with clean liquid. Reinstall the
fill plug (6, Figure 2) and tighten it.

Refer to OPERATION, Section C, before putting
the pump back into service.

LUBRICATION

Seal Assembly

(Figures 2 and 4)

Fill the grease cup (11) through the grease fitting
with No. 2 lithium base grease until grease es-
capes from the relief hole. Turn the grease cup arm
counterclockwise until it is at the top of the stem;
this will release the spring to apply grease to the
seal (see Figure 4).

GREASE

FITTING

CROSS

ARM

POSITION

WHEN

EMPTY

POSITION

FOR

FILLING

POSITION

WHEN

IN USE

RELIEF

HOLE

Figure 4. Automatic Lubricating Grease Cup

Engine

Consult the literature supplied with the engine, or
contact your local engine representative.

Advertising