OM-05670

SUPER U SERIES

MAINTENANCE & REPAIR

PAGE E - 12

IMPELLER

SHAFT

STATIONARY

SEAT

STATIONARY

ELEMENT

DRIVE BAND

BELLOWS

IMPELLER

SHIMS

SPRING

ROTATING

ELEMENT

SEAL

PLATE

O‐RINGS

IMPELLER

RETAINER

Figure 6. 46512-192 Cartridge Seal Assembly

This seal is not designed for operation at
temperatures above 160

_ F (71_ C). Do

not use at higher operating temperatures.

Lubricate the stationary seat O‐rings with water or
light oil, and install them in the stationary seat. In­
stall the stationary seal element in the stationary
seat. Press this stationary subassembly into the
front of the seal plate until it seats squarely against
the bore shoulder.

Install the seal plate gasket (3). Position the seal
plate (2) and stationary seat over the shaft, and se­
cure it to the bearing housing with the hardware (4
and 5). Be careful not to damage the stationary
element on the shaft threads.

NOTE

It is recommended that a tapered sleeve be
installed over the threads of the impeller shaft to
ease installation of the rotating seal components.

Lubricate the shaft (24) with a small amount of light
oil and slide the rotating subassembly (consisting
of rotating element, bellows and retainer), onto the
shaft until the seal faces contact.

Install the seal spring. Lubricate the seal as indi­
cated in LUBRICATION after the impeller is in­
stalled.

Impeller Installation and Adjustment.

(Figure 2)

Inspect the impeller, and replace it if cracked or
badly worn. Inspect the impeller and shaft threads
for dirt or damage, and clean or dress the threads
as required.