Gorman-Rupp Pumps U6B60S-B 1289612 and up User Manual

Page 40

Advertising
background image

OM-05669

SUPER U SERIES

MAINTENANCE & REPAIR

PAGE E - 17

the middle of the gauge. When lubrication is re­
quired, add SAE No. 30 non‐detergent

oil through

the hole for the air vent (13). Do not over‐lubricate.
Over‐lubrication can cause the bearings to over‐
heat, resulting in premature bearing failure.

NOTE

The white reflector in the sight gauge must be posi­
tioned horizontally to provide proper drainage.

Under normal conditions, drain the bearing hous­
ing once each year and refill with clean oil. Change
the oil more frequently if the pump is operated con­
tinuously or installed in an environment with rapid
temperature change.

Monitor the condition of the bearing lubri­
cant regularly for evidence of rust or mois­
ture condensation. This is especially im­
portant in areas where variable hot and
cold temperatures are common.

For cold weather operation, consult the factory or a
lubricant supplier for the recommended grade of
oil.

Power Source

Consult the literature supplied with the power
source, or contact your local power source repre­
sentative.

Advertising
This manual is related to the following products: