Operation – Gorman-Rupp Pumps 13C3-E5 3P All serial numbers User Manual

Page 16

Advertising
background image

SELF-PRIMING CENTRIFUGAL PUMPS

OM--04760

OPERATION

PAGE C -- 1

OPERATION --- SECTION C

Review all SAFETY information in Section A.

Follow the instructions on all tags, labels and de-
cals attached to the pump.

Do not attempt to pump any liquids the

pump has not been designed for, and

which may damage the pump or endan-

ger personnel as a result of pump fail-

ure.

Pump speed and operating conditions

must be within the performance range

shown on the curve in Parts Lists manual.

Refer to the pump Specification Data Sheet or the
accompanying Parts List Manual for the specific
performance for your pump.

PRIMING

Install the pump and piping as described in

IN-

STALLATION. Make sure that the piping connec-
tions are tight, and that the pump is securely
mounted. Check that the pump is properly lubri-
cated (see

LUBRICATION in the MAINTENANCE

AND REPAIR manual).

The pump is self-priming, but it should never be op-
erated unless there is liquid in the pump casing.

Never operate the pump unless there is liq-

uid in the pump casing. The pump will not

prime when dry. Extended operation of a

dry pump will destroy the seal assembly.

Add liquid to the pump casing when:

1. The pump is being put into service for the

first time.

2. The pump has not been used for a consider-

able length of time.

3. The liquid in the pump casing has evapo-

rated.

Once the pump casing has been filled, the pump
will prime and reprime as necessary.

After filling the pump casing, reinstall

and tighten the fill plug. Do not attempt

to operate the pump unless all connect-

ing piping is securely installed. Other-

wise, liquid in the pump forced out

under pressure could cause injury to

personnel.

To fill the pump, remove the pump casing fill cover
or fill plug in the top of the casing, and add clean
liquid until the casing is filled. Replace the fill cover
or fill plug before operating the pump.

STARTING

Starting procedures will vary slightly depending on
the pump application, type of priming device, and
type of drive. Consult the operations manual fur-
nished with the power source.

Rotation

The correct direction of pump rotation is indicated
by an arrow on the pump body or accompanying
decals. If the pump is operated in the wrong direc-
tion, the impeller could become loosened from the
shaft and seriously damage the pump.

The pump must operate in the direction in-

dicated by the arrow on the pump, or ac-

Advertising