Safety - section a – Gorman-Rupp Pumps 13A52-GX390 1371656 and up User Manual

Page 6

Advertising
background image

10 SERIES

OM−04730

PAGE A − 1

SAFETY

SAFETY − SECTION A

This information applies to 10 Series en-
gine driven pumps. Refer to the manual
accompanying the engine before at-
tempting to begin operation.

This manual will alert personnel to
known procedures which require spe-
cial attention, to those which could
damage equipment, and to those which
could be dangerous to personnel.

How-

ever, this manual cannot possibly antici-
pate and provide detailed instructions
and precautions for every situation that
might occur during maintenance of the
unit. Therefore, it is the responsibility of
the owner/maintenance personnel to
ensure that only safe, established main-
tenance procedures are used, and that
any procedures not addressed in this
manual are performed only after estab-
lishing that neither personal safety nor
pump integrity are compromised by
such practices.

Before attempting to open or service the
pump:

1. Familiarize yourself with this man-

ual.

2. Shut down the engine and discon-

nect the spark plug wire to ensure
that the pump will remain inopera-
tive.

3. Allow the pump to completely cool

if overheated.

4. Check the temperature before

opening any covers, plates, or
plugs.

5. Close the suction and discharge

valves.

6. Vent the pump slowly and cau-

tiously.

7. Drain the pump.

This pump is designed to handle most
non-volatile, non-flammable liquids
containing specified entrained solids.
Do not attempt to pump volatile, corro-
sive, or flammable liquids which may
damage the pump or endanger person-
nel as a result of pump failure.

Use lifting and moving equipment in
good repair and with adequate capacity
to prevent injuries to personnel or dam-
age to equipment. The bail is intended
for use in lifting the pump assembly
only. Suction and discharge hoses and
piping must be removed from the pump
before lifting.

After the pump has been positioned,
make certain that the pump and all pip-
ing connections are tight, properly sup-
ported and secure before operation.

Do not operate the pump against a
closed discharge valve for long periods
of time. If operated against a closed dis-
charge valve, pump components will
deteriorate, and the liquid could come
to a boil, build pressure, and cause the
pump casing to rupture or explode.