Gorman-Rupp Pumps 16C2-F4L 1237525 thru 1319250 User Manual

Page 40

Advertising
background image

10 SERIES

OM−00725

MAINTENANCE & REPAIR

PAGE E − 16

Bearings

(Figure 2)

The intermediate was fully lubricated when
shipped from the factory. Check the oil level regu-
larly through the sight gauge (34)

and maintain it at

the middle of the gauge. When lubrication is re-
quired, add SAE No. 30 non-detergent oil through
the hole for the oil hole cover (20). Do not over-lu-
bricate. Over-lubrication can cause the bearings to
over-heat, resulting in premature bearing failure.

NOTE

The white reflector in the sight gauge must be posi-
tioned horizontally to provide proper drainage.

Under normal conditions, drain the intermediate
once each year and refill with approximately 7−1/2
ounces (22 ml) of clean oil. Change the oil more fre-
quently if the pump is operated continuously or in-

stalled in an environment with rapid temperature
change.

Monitor the condition of the bearing lubri-
cant regularly for evidence of rust or mois-
ture condensation. This is especially im-
portant in areas where variable hot and
cold temperatures are common.

For cold weather operation, consult the factory or a
lubricant supplier for the recommended grade of
oil.

Engine

Consult the literature supplied with the power
source, or contact your local Deutz engine repre-
sentative.

Advertising