Alignment – Gorman-Rupp Pumps 16A2-F3L 1317807 and up User Manual

Page 15

Advertising
background image

OM−00698

10 SERIES

PAGE B − 8

INSTALLATION

Air Release Valve Installation

The Automatic Air Release Valve must be inde-
pendently mounted in a horizontal position and
connected to the discharge line of the self-priming
centrifugal pump (see Figure 6).

NOTE

If the Air Release Valve is to be installed on a staged

pump application, contact the factory for specific

installation instructions.

DISCHARGE PIPE

DISCHARGE

CHECK VALVE

PUMP DISCHARGE

SELF-PRIMING

CENTRIFUGAL

PUMP

SUCTION

LINE

SUPPORT

BRACKET

CLEAN-OUT

COVER

INSTALL AIR RELEASE VALVE

IN HORIZONTAL POSITION

90

_ LONG

RADIUS

ELBOW

WET WELL

OR SUMP

BLEED LINE 1"
(25,4 MM) DIA. MIN.
(CUSTOMER FUR-
NISHED) EXTEND 6"
(152 MM) BELOW
PUMP OFF LIQUID
LEVEL

Figure 6. Typical Automatic Air Release Valve Installation

The valve inlet line must be installed between the

pump discharge port and the non-pressurized side

of the discharge check valve. The valve inlet is at

the large end of the valve body, and is provided

with standard 1 inch NPT pipe threads.

The valve outlet is located at the opposite end of

the valve, and is also equipped with standard 1

inch NPT pipe threads. The outlet should be con-

nected to a bleed line which slopes back to the wet

well or sump. The bleed line must be the same size

as the inlet piping, or larger. If piping is used for the

bleed line, avoid the use of elbows whenever pos-

sible.

NOTE

It is recommended that each Air Release Valve be
fitted with an independent bleeder line directed
back to the wet well. However, if multiple Air Re-
lease Valves are installed in a system, the bleeder
lines may be directed to a common manifold pipe.
Contact your Gorman-Rupp distributor or the Gor-
man-Rupp Company for information about installa-
tion of an Automatic Air Release Valve for your spe-
cific application.

ALIGNMENT

The alignment of the pump and the engine is criti-
cal for trouble-free mechanical operation. See Sec-
tion E, Securing Intermediate And Drive Assem-
bly To Engine for detailed information.

Advertising