OM−00701

10 SERIES

PAGE B − 6

INSTALLATION

move plates, covers, gauges, or fittings
from an over-heated pump. Liquid with-
in the pump can reach boiling tempera-
tures, and vapor pressure within the
pump can cause parts being disen-
gaged to be ejected with great force. Af-
ter the pump completely cools, drain the
liquid from the pump by removing the
casing drain plug. Use caution when re-
moving the plug to prevent injury to per-
sonnel from hot liquid.

AUTOMATIC AIR RELEASE VALVE

When properly installed, a Gorman-Rupp Auto-
matic Air Release Valve will permit air to escape
through the bypass line and then close automati-
cally when the pump is fully primed and pumping
at full capacity.

Some leakage (1 to 5 gallons [3.8 to 19
liters] per minute) will occur when the
valve is fully closed. Be sure the bypass
line is directed back to the wet well or
tank to prevent hazardous spills.

Consult the manual accompanying the Air Release
Valve for additional information on valve installation
and performance.

ALIGNMENT

The alignment of the pump and its power source is
critical for trouble-free mechanical operation. In
either a flexible coupling or V-belt driven system,
the driver and pump must be mounted so that their
shafts are aligned with and parallel to each other. It
is imperative that alignment be checked after the
pump and piping are installed, and before opera-
tion.

NOTE

Check Rotation, Section C, before final alignment
of the pump.

When mounted at the Gorman-Rupp factory, driver
and pump are aligned before shipment. Misalign-
ment will occur in transit and handling. Pumps
must be checked and realigned before operation.
Before checking alignment, tighten the foundation
bolts. The pump casing feet and/or pedestal feet,
and the driver mounting bolts should also be tightly
secured.

When checking alignment, disconnect
the power source to ensure that the
pump will remain inoperative.

Adjusting the alignment in one direction
may alter the alignment in another direc-
tion. Check each procedure after altering
alignment.

Coupled Drives

When using couplings, the axis of the power
source must be aligned to the axis of the pump
shaft in both the horizontal and vertical planes.
Most couplings require a specific gap or clearance
between the driving and the driven shafts. Refer to
the coupling manufacturer’s service literature.

Align spider insert type couplings by using calipers
to measure the dimensions on the circumference
of the outer ends of the coupling hub every 90

_.

The coupling is in alignment when the hub ends
are the same distance apart at all points (see Fig-
ure B−3).

Figure B−3. Aligning Spider-Type Couplings

Align non-spider type couplings by using a feeler
gauge or taper gauge between the coupling halves