INSTALLATION

every 90

_. The coupling is in alignment when the

hubs are the same distance apart at all points (see
Figure B-4).

Figure B-4. Aligning Non‐Spider‐Type

Couplings

Check parallel adjustment by laying a straightedge
across both coupling rims at the top, bottom, and
side. When the straightedge rests evenly on both
halves of the coupling, the coupling is in horizontal
parallel alignment. If the coupling is misaligned,
use a feeler gauge between the coupling and the
straightedge to measure the amount of misalign­
ment.

Belt Drives

When using belt drives, the power source and the
pump must be parallel. Use a straightedge along
the sides of the pulleys to ensure that the pulleys
are properly aligned (see Figure B-5). In drive sys­
tems using two or more belts, make certain that the

belts are a matched set; unmatched sets will cause
accelerated belt wear.

MISALIGNED:

SHAFTS

NOT PARALLEL

MISALIGNED:

SHAFTS

NOT IN LINE

ALIGNED: SHAFTS

PARALLEL AND

SHEAVES IN LINE

Figure B-5. Alignment of V‐Belt Driven

Pumps

Tighten the belts in accordance with the belt manu­
facturer's instructions. If the belts are too loose,
they will slip; if the belts are too tight, there will be
excessive power loss and possible bearing failure.
Select pulleys that will match the proper speed ra­
tio; overspeeding the pump may damage both
pump and power source.

Do not operate the pump without the
guard in place over the rotating parts.
Exposed rotating parts can catch cloth­
ing, fingers, or tools, causing severe in­
jury to personnel.