OM−01830

10 SERIES

PAGE B − 10

INSTALLATION

ELECTRICAL CONNECTIONS

Before connecting a motor to the incoming power,
check that the electrical service available matches
the pump motor requirements stamped on the mo-
tor nameplate.

If rotation is incorrect on a three-phase motor, have
a qualified electrician interchange any two of the
three phase wires to change direction. If rotation is
incorrect on a single-phase motor, consult the lit-
erature supplied with the motor for specific instruc-
tions.

The electrical power used to operate the
pump is high enough to cause injury or

death. Obtain the services of a qualified
electrician to make all electrical con-
nections.

Do not install and operate a non-explo-
sion proof motor in an explosive atmo-
sphere. Install, connect, and operate
the motor in accordance with The Na-
tional Electrical Code and all local
codes. If there is a conflict between the
instructions in the manual accompany-
ing the unit and The National Electrical
Code or the applicable local code, The
National or local code shall take prece-
dence.