OM−00615

10 SERIES

PAGE B − 5

INSTALLATION

tween the pump discharge and the check valve. A
self-priming centrifugal pump will not prime if
there is sufficient static liquid head to hold the dis-
charge check valve closed.

NOTE

The bypass line should be sized so that it does not
affect pump discharge capacity; however, the by-
pass line should be at least 1 inch (25,4 mm) in di-
ameter to minimize the chance of plugging.

In low discharge head applications (less than 30
feet (9,1 m)), it is recommended that the bypass
line be run back to the wet well, and located 6
inches below the water level or cut-off point of the
low level pump. In some installations, this bypass
outline may be terminated with a six-to-eight foot
(1,8 to 2,4 m) length of 1-1/4 inch (31,8 mm) I.D.
smooth-bore hose; air and liquid vented during
the priming process will then agitate the hose and
break up any solids, grease, or other substances
likely to cause clogging.

A bypass line that is returned to a wet well
must be secured against being drawn into
the pump suction inlet.

It is also recommended that pipe unions be in-
stalled at each 90

_ elbow in a bypass line to ease

disassembly and maintenance.

In high discharge head applications (more than
30 feet (9,1 m), an excessive amount of liquid may
be bypassed and forced back to the wet well under
the full working pressure of the pump; this will re-
duce overall pumping efficiency. Therefore, it is
recommended that a Gorman-Rupp Automatic
Air Release Valve be installed in the bypass line.

Gorman-Rupp Automatic Air Release Valves are
reliable, and require minimum maintenance. See
Automatic Air Release Valves in this section for
installation and theory of operation of the Auto-
matic Air Release Valve. Consult your Gorman-
Rupp distributor, or contact the Gorman-Rupp

Company for selection of an Automatic Air Release
Valve to fit your application.

If the installation involves a flooded suction such as
a below-ground lift station. A pipe union and manu-
al shut-off valve may be installed in the bleed line to
allow service of the valve without shutting down the
station, and to eliminate the possibility of flooding.
If a manual shut-off valve is installed anywhere in
the air release piping, it must be a full-opening ball
type valve to prevent plugging by solids.

If a manual shut-off valve is installed in
a bypass line, it must not be left closed
during operation. A closed manual shut-
off valve may cause a pump which has
lost prime to continue to operate with-
out reaching prime, causing dangerous
overheating and possible explosive
rupture of the pump casing. Personnel
could be severely injured

.

Allow an over-heated pump to cool be-
fore servicing

.

Do not

remove plates,

covers, gauges, or fittings from an over-
heated pump. Liquid within the pump
can reach boiling temperatures, and va-
por pressure within the pump can cause
parts being disengaged to be ejected
with great force. After the pump cools,
drain the liquid from the pump by re-
moving the casing drain plug. Use cau-
tion when removing the plug to prevent
injury to personnel from hot liquid.

AUTOMATIC AIR RELEASE VALVE

When properly installed and correctly adjusted to
the specific hydraulic operating conditions of the
application, the Gorman-Rupp Automatic Air Re-
lease Valve will permit air to escape through the by-
pass line, and then close automatically when the
pump is fully primed and pumping at full capacity.