Gorman-Rupp Pumps 11 1/2A2-E2 1P 1046838 and up User Manual

Page 15

Advertising
background image

OM-04092

10 SERIES

PAGE B - 8

INSTALLATION

ELECTRICAL CONNECTIONS

Before connecting the motor to the incoming
power, check that the electrical service available
matches the pump motor requirements stamped
on the motor nameplate.

The electrical power used to operate
this pump is high enough to cause inju­
ry or death. Obtain the services of a qu­
alified electrician to make all electrical
connections.

Do not install and operate a non‐explo­
sion proof motor in an explosive atmo­
sphere. Install, connect, and operate
the motor in accordance with The Na­
tional Electric Code and all local codes.
If there is a conflict between the instruc­
tions in the manual accompanying the
unit and The National Electric Code or
the applicable local code, The National
or local code shall take precedence.

Refer to the following motor data before making
electrical connections.

VOLTAGE

PHASE

HP

Hz

RPM

THERMAL

OVERLOAD

115/230

230/460

1

3

2

2

60

60

3450

3450

20 AMPS

N/A