OM−00780

80 SERIES

PAGE B − 6

INSTALLATION

the belts are a matched set; unmatched sets will
cause accelerated belt wear.

MISALIGNED:

SHAFTS

NOT PARALLEL

MISALIGNED:

SHAFTS

NOT IN LINE

ALIGNED: SHAFTS

PARALLEL AND

SHEAVES IN LINE

Figure 3C. Alignment of V-Belt Driven Pumps

Tighten the belts in accordance with the belt manu-
facturer’s instructions. If the belts are too loose,
they will slip; if the belts are too tight, there will be
excessive power loss and possible bearing failure.
Select pulleys that will match the proper speed ra-
tio; overspeeding the pump may damage both
pump and power source.

Do not operate the pump without the
shields and/or guards in place over the
drive shaft, belts, and/or couplings, or
other rotating parts. Exposed rotating
parts can catch clothing, fingers, or
tools, causing severe injury to person-
nel.

GROUNDING

If the pump has been approved to pump volatile or
flammable liquids, the unit must be grounded by
attaching the ground wire assembly to a ground
rod in order to eliminate electrostatic build-up by
the liquid being pumped. Install the ground rod in
accordance with the National Electrical Codes and
all local codes. Be sure the fastening device makes
a tight electrical connection with the rod and the
pump.

Inspect and test the ground wire assembly
for conductivity. replace broken or frayed
wire before resuming operation.