background image

OM−00789

80 SERIES

PAGE B − 2

INSTALLATION

ing, check for loose hardware at mating sur-
faces.

c. Carefully read all warnings and cautions con-

tained in this manual or affixed to the pump,
and perform all duties indicated.

d. Check levels and lubricate as necessary. Re-

fer to LUBRICATION in the MAINTENANCE
AND REPAIR section of this manual and per-
form duties as instructed.

e. If the pump and

motor have been stored for

more than 12 months, some of the compo-
nents or lubricants may have exceeded their
maximum shelf life. These must be inspected
or replaced to ensure maximum pump serv-
ice.

If the maximum shelf life has been exceeded, or if
anything appears to be abnormal, contact your
Gorman-Rupp distributor or the factory to deter-
mine the repair or updating policy. Do not put the
pump into service until appropriate action has
been taken.

The electrical power used to operate
this pump is high enough to cause inju-
ry or death. Obtain the services of a qu-
alified electrician to troubleshoot, test
and/or service the electrical compo-
nents of this pump.

POSITIONING PUMP

Lifting

Pump unit weights will vary depending on the
mounting and drive provided. Check the shipping
tag on the unit packaging for the actual weight, and
use lifting equipment with appropriate capacity.
Drain the pump and remove all customer-installed
equipment such as suction and discharge hoses
or piping before attempting to lift existing, installed
units.

The pump assembly can be seriously
damaged if the cables or chains used to lift
and move the unit are improperly wrapped
around the pump.

Mounting

Locate the pump in an accessible place as close as
practical to the liquid being pumped. Level mount-
ing is essential for proper operation.

The intermediate is equipped with mounting foot
holes for mounting the pump to a base.

SUCTION AND DISCHARGE PIPING

Pump performance is adversely effected by in-
creased suction lift, discharge elevation, and fric-
tion losses. See the performance curve and oper-
ating range shown on Page E-1 to be sure your
overall application allows pump to operate within
the safe operation range.

Materials

Either pipe or hose maybe used for suction and
discharge lines; however, the materials must be
compatible with the liquid being pumped. If hose is
used in suction lines, it must be the rigid-wall, rein-
forced type to prevent collapse under suction. Us-
ing piping couplings in suction lines is not recom-
mended.

Line Configuration

Keep suction and discharge lines as straight as
possible to minimize friction losses. Make mini-
mum use of elbows and fittings, which substan-
tially increase friction loss. If elbows are necessary,
use the long-radius type to minimize friction loss.

Connections to Pump

Before tightening a connecting flange, align it ex-
actly with the pump port. Never pull a pipe line into
place by tightening the flange bolts and/or cou-
plings.

Advertising