80 SERIES

OM−00752

PAGE B − 5

INSTALLATION

Bypass Lines

If a system check valve is used due to high dis-
charge head, it may be necessary to vent trapped
air from the top of the pump during the priming
process. This may be accomplished by installing a
bypass line from the top of the pump, back to the
source of liquid. The end of the bypass line must be
submerged. The line must be large enough to pre-
vent clogging, but not so large as to affect pump
discharge capacity.

ELECTRICAL CONNECTIONS

Before connecting the motor to the incoming
power, check that the electrical service available
matches the pump motor requirements stamped
on the motor nameplate.

The electrical power used to operate

this pump is high enough to cause inju-
ry or death. Obtain the services of a qu-
alified electrician to make all electrical
connections.

Do not install and operate a non-explo-
sion proof motor in an explosive atmo-
sphere. Install, connect, and operate
the motor in accordance with The Na-
tional Electric Code and all local codes.
If there is a conflict between the instruc-
tions in the manual accompanying the
unit and The National Electric Code or
the applicable local code, The National
or local code shall take precedence.

Refer to the following motor data before making
electrical connections.

VOLTAGE

PHASE

HP

Hz

RPM

FRAME

115/230

1

60

3450

56

MODEL

81 1/2D3−E.75 1P