Gorman-Rupp Pumps 83B2-B 1063841 and up User Manual

Page 14

Advertising
background image

80 SERIES

OM−00868

PAGE B − 7

INSTALLATION

er at the measured belt span. Set the small O-ring
on the deflection force scale to zero.

Place the tension tester squarely on the belt at the
center of the belt span. Apply force on the plunger,
perpendicular to the belt span, until the bottom of
the large O-ring is even with the top of the next belt,
or with the bottom of a straight edge laid across the
sheaves.

Read the force applied from the bottom of the small

O-ring on the deflection force scale. Compare this

force with the value shown in Table 1 or 2 and ad-

just the tension accordingly. Note that the tension

for new belts is higher than that for used belts to

allow for expected belt stretching. Do not over-ten-

sion used belts to the higher deflection forces

shown for new belts.

Advertising